Rashtriya Chemicals And Fertilizers Limited
Important Info
AOC Description
Rashtriya Chemicals And Fertilizers Limited has published Notice Inviting Tender For Supply Of Ptfe Lined Pipes And Fitting For Sap Plant , Supply Material At Rcf Trombay Unit ( As Per Technical Specifications Annexure-Iii ) , Sap- Pipe ( Ptfe Lined ) Size: 8 ( 200 Nb ) End Connections: Flanged , Flat Faced . Fixed Flange On One Side & Swivel ( Loose ) Flange On Other Side Pipe:Astm A-106 Gr B Sch 40 Pipe Length Face To Face = 1250 Mm Flange Material: Astm- A 105 Flange Dimensions: As Per Ansi B 16 . 5 / Asa 150 . Lining : Ptfe / Pfa Lining As Per Astm F- 1545-95 Lining Thickness: 3 Mm Minimum . Ptfe / Pfa: Astm D -1457 Type Iii / Ii . Tests : Spark Test @ 15 Kv And Hydrotest@ 10 Kg / Cm2 Painting : External Sufaces Shall Be Epoxy Painted With Primer Of 40 Micron Dft Followed By Finish Paint ( Colour-Dark Violet ) Of 40 Micron Dft Note: 1 ) Vendor Shall Submit Test Reports / Certificates ( Hydrostatic , Electrostatic Test , External Paint Dft , Material Test Certificates ) Along With The Supply . 2 ) Packing: Flange Shall Be Closed At Both The End Suitably Before Dispatch To Avoid Damage Of The Lining . , Pipe 8In Dia Ptfe Lined . Flange To Flange Distance After Lining 1000 Mm Pipe Material: Astm A 106 Gr . B Sch 40 . Flange Material: As Per Astm A 105 , Dimensions To Ansi B 16 . 5 / Asa 150 . One Side Fix & Other Side Loose Flange . Lining : Ptfe / Pfa Lining As Per Astm F- 1545-95 . Lining Thickness: 3 Mm Minimum . Fitting : Astm A234 Wpb . Ptfe / Pfa : Astm D -1457 Type Iii . Tests : 15 Kv Spark Test & 10 Kg / Cm2 Hydrotest , Sap- Pipe ( Ptfe Lined ) Size: 8 ( 200 Nb ) End Connections: Flanged , Flat Faced . Fixed Flange On One Side & Swivel ( Loose ) Flange On Other Side Pipe:Astm A-106 Gr B Sch 40 Pipe Length Face To Face = 700 Mm Flange Material: Astm- A 105 Flange Dimensions: As Per Ansi B 16 . 5 / Asa 150 . Lining : Ptfe / Pfa Lining As Per Astm F- 1545-95 Lining Thickness: 3 Mm Minimum . Ptfe / Pfa: Astm D -1457 Type Iii . Tests : Spark Test @ 15 Kv And Hydrotest@ 10 Kg / Cm2 Painting : External Sufaces Shall Be Epoxy Painted With Primer Of 40 Micron Dft Followed By Finish Paint ( Colour-Dark Violet ) Of 40 Micron Dft Note: 1 ) Vendor Shall Submit Test Reports / Certificates ( Hydrostatic , Electrostatic Test , External Paint Dft , Material Test Certificates ) Along With The Supply . 2 ) Packing: Flange Shall Be Closed At Both The End Suitably Before Dispatch To Avoid Damage Of The Lining . , Sap- Pipe ( Ptfe Lined ) Size: 8 ( 200 Nb ) End Connections: Flanged , Flat Faced . Fixed Flange On One Side & Swivel ( Loose ) Flange On Other Side Pipe:Astm A-106 Gr B Sch 40 Pipe Length Face To Face = 350 Mm Flange Material: Astm- A 105 Flange Dimensions: As Per Ansi B 16 . 5 / Asa 150 . Lining : Ptfe / Pfa Lining As Per Astm F- 1545-95 Lining Thickness: 3 Mm Minimum . Ptfe / Pfa: Astm D -1457 Type Iii . Tests : Spark Test @ 15 Kv And Hydrotest@ 10 Kg / Cm2 Painting : External Sufaces Shall Be Epoxy Painted With Primer Of 40 Micron Dft Followed By Finish Paint ( Colour-Dark Violet ) Of 40 Micron Dft Note: 1 ) Vendor Shall Submit Test Reports / Certificates ( Hydrostatic , Electrostatic Test , External Paint Dft , Material Test Certificates ) Along With The Supply . 2 ) Packing: Flange Shall Be Closed At Both The End Suitably Before Dispatch To Avoid Damage Of The Lining . , Sap- Pipe ( Ptfe Lined ) Size: 8 ( 200 Nb ) End Connections: Flanged , Flat Faced . Fixed Flange On One Side & Swivel ( Loose ) Flange On Other Side Pipe:Astm A-106 Gr B Sch 40 Pipe Length Face To Face = 450 Mm Flange Material: Astm- A 105 Flange Dimensions: As Per Ansi B 16 . 5 / Asa 150 . Lining : Ptfe / Pfa Lining As Per Astm F- 1545-95 Lining Thickness: 3 Mm Minimum . Ptfe / Pfa: Astm D -1457 Type Iii . Tests : Spark Test @ 15 Kv And Hydrotest@ 10 Kg / Cm2 Painting : External Sufaces Shall Be Epoxy Painted With Primer Of 40 Micron Dft Followed By Finish Paint ( Colour-Dark Violet ) Of 40 Micron Dft Note: 1 ) Vendor Shall Submit Test Reports / Certificates ( Hydrostatic , Electrostatic Test , External Paint Dft , Material Test Certificates ) Along With The Supply . 2 ) Packing: Flange Shall Be Closed At Both The End Suitably Before Dispatch To Avoid Damage Of The Lining . , Pfa Lined M . S . Concentric Reducer . Size : 8X6 In Flange To Flange Distance After Lining 280 Mm Flange Material: As Per Astm A 105 Dimensions To Ansi B 165 / Asa 150 . Lining: Pfa Lining As Per Astm F- 1545-95 . Lining Thickness: 3 Mm Minimum . Fitting: Astm A234 Wpb . Pfa: Astm D -1457 Type Iii . Tests : 15 Kv Spark Test & 10 Kg / Cm2 Hydrotest , M . S . Teflon Lined Concentric Reducer . Size: 6X4 In Flange To Flange Disance After Lining 230 Mm Flange Material: As Per Astm A 105 , Dimensions To Ansi B 16 . 5 / Asa 150 . Lining : Ptfe / Pfa Lining As Per Astm F- 1545-95 . Lining Thickness: 3 Mm Minimum . Fitting : Astm A234 Wpb . Ptfe / Pfa : Astm D -1457 Type Iii . Tests : 15 Kv Spark Test& 10 Kg / Cm2 Hydrotest , M . S . Teflon Lined Concentric Reducer . Size: 4X3 In Flange To Flange Disance After Lining 180 Mm Flange Material: As Per Astm A 105 , Dimensions To Ansi B 16 . 5 / Asa 150 . Lining : Ptfe / Pfa Lining As Per Astm F- 1545-95 . Lining Thickness: 3 Mm Minimum . Fitting : Astm A234 Wpb . Ptfe / Pfa : Astm D -1457 Type Iii . Tests : 15 Kv Spark Test& 10 Kg / Cm2 Hydrotest , Tee Equal 6 X6 X3 In Pfa Lined ( Perfluoro Alkoxy ) With Flat Faced Fixed Fnges . Flange To Flange Distance For 6In Flanges After Lining 406 Mm . Flnge Material: As Per Astm A 105 , Dimensions To Ansi B 16 . 5 / Asa 150 . Lining : Ptfe / Pfa Lining As Per Astm F- 1545-95 . Lining Thickness: 3 Mm Minimum . Fitting : Astm A234 Wpb . Ptfe / Pfa : Astm D -1457 Type Iii . Tests : 15 Kv Spark Test& 10 Kg / Cm2 Hydrotest , Sap- Concentric Reducer ( Ptfe Lined ) Size: 6 X 3 Dia , End Connections: Flanged , Flat Faced . Fixed Flange On One Side & Swivel ( Loose ) Flange On Other Side Reducer: Astm A234 Wpb Reducer Dimensions: As Per Ansi B16 . 9 Flange Material: Astm- A 105 Flange Dimensions: As Per Ansi B 16 . 5 / Asa 150 . Face To Face : 230 Mm Lining : Ptfe / Pfa Lining As Per Astm F- 1545-95 Lining Thickness: 3 Mm Minimum . Ptfe / Pfa: Astm D -1457 Type Iii . Tests : Spark Test @ 15 Kv And Hydrotest@ 10 Kg / Cm2 Painting : External Sufaces Shall Be Epoxy Painted With Primer Of 40 Micron Dft Followed By Finish Paint ( Colour-Dark Violet ) Of 40 Micron Dft Note: 1 ) Vendor Shall Submit Test Reports / Certificates ( Hydrostatic , Electrostatic Test , External Paint Dft , Material Test Certificates ) Along With The Supply . 2 ) Packing: Flange Shall Be Closed At Both The End Suitably Before Dispatch To Avoid Damage Of The Lining .. Last date of submission for this tender is 2020-10-30. This is a Other Adhesives And Sealants tender in Rcf Ltd Chembur, Maharashtra
Insurance Surety Bond
Fast, Reliable & Accepted for EMD/PBG
- Zero BG Limit Impact
- Accepted in All Tenders
- Quick Online Quote
Tender Documents
- Tender Document 1html
Unlock the Tender details for free
Bidder Details
| Bidder Name | Technical Bid | Financial Bid | AOC | Bid Value | Rank |
|---|---|---|---|---|---|
| Sharma infra projects pvt ltd | ₹1,24,50,000.00 | L1 | |||
| Verma constructions ltd | ₹1,31,00,000.00 | L2 | |||
| Nair engineering works | ₹1,38,75,000.00 | L3 | |||
| Iyer industrial solutions | ₹1,43,20,000.00 | L4 |
Unlock the Tender details for free

